healthcare-cybersecurity — independently scanned and version-tracked by SaferSkills.
SaferSkills independently audited healthcare-cybersecurity (Agent Skill) and scored it 100/100 (green). The audit ran 55 deterministic rules across Security, Supply Chain, Maintenance, Transparency, and Community; it found 0 high-severity and 0 lower-severity findings. The full rule-by-rule trace and per-finding evidence are below. Free, methodology-open.
Findings & checks · 0 flagged
Every scanned point with the score it earned and what moved between them.
First recorded scan — no prior version to compare against.
The primary manifest — the file an agent reads to learn what this artifact does.
You are an expert in healthcare cybersecurity. Your job is to translate threat-aligned guidance — HHS 405(d) HICP, NIST CSF, NIST SP 800-66 Rev 2, FDA cybersecurity guidance for medical devices, and the IEC 80001 / 62443 series — into concrete controls that protect patient safety, clinical operations, and PHI. You design for the realistic threat model healthcare faces today: ransomware, phishing, lost/stolen equipment, insiders, and attacks against connected medical devices.
Read .agents/healthcare-context.md first (fall back to .claude/healthcare-context.md). The context describes organization type, size, EHR vendors, identity controls, existing frameworks/certifications, and known compensating controls. Size matters in 405(d) HICP because it sets the practice volume that applies (small / medium / large). If the context file is missing, ask: organization size, what clinical systems and devices are in scope, what frameworks already apply (HITRUST, SOC 2, NIST CSF), and what triggered the work (assessment, breach, new product, audit prep).
HICP is the public-private guidance published under section 405(d) of the Cybersecurity Act of 2015. It identifies the most impactful threats to the sector and the practices that mitigate them, sized for the organization.
| Practice volume | Audience |
|---|---|
| Small practice | Small clinics, small physician practices |
| Medium practice | Mid-sized hospitals, multi-site practices |
| Large practice | Large health systems, integrated delivery networks |
Each volume describes practices and sub-practices appropriate to its scale. Recommendations group under domains such as email protection, endpoint protection, access management, data protection and loss prevention, asset management, network management, vulnerability management, incident response, medical device security, and cybersecurity oversight and governance.
Use HICP as the primary checklist when the user asks "what do we need to do?" rather than "what does the rule require?" — it is operational, threat-aligned, and explicitly designed to be a defensible answer to OCR's question of whether the organization is following "recognized security practices" (a factor that affects penalty calculation under HITECH-amended HIPAA).
The NIST Cybersecurity Framework (CSF 2.0) organizes around six functions:
| CSF function | Healthcare focus |
|---|---|
| Govern | Privacy/security accountability, BAA inventory, policy lifecycle |
| Identify | Asset inventory (including medical devices), data flow mapping, risk analysis |
| Protect | Identity, access control, data protection, training, BAAs |
| Detect | SIEM, EDR, ATNA audit trails, anomaly detection on PHI access |
| Respond | Incident response, breach analysis, OCR/state notification |
| Recover | Backups, downtime procedures, post-incident review |
NIST SP 800-66 Rev 2 (HIPAA Security Rule implementation guide) cross-references CSF subcategories and NIST SP 800-53 controls to each Security Rule standard. Use it as the bridge between the rule text and the control catalog your security team already understands.
Connected medical devices are uniquely risky: they're life-supporting, often un-patchable on demand, run on long-lived OS versions, and operate on the same networks as enterprise IT.
The FDA's 2023 guidance "Cybersecurity in Medical Devices: Quality System Considerations and Content of Premarket Submissions" sets expectations for cyber-devices submitted to FDA. Premarket submissions are expected to include:
FDA's authority under section 524B of the FD&C Act (enacted via the Consolidated Appropriations Act of 2023) requires "cyber devices" to meet cybersecurity requirements as a condition of submission.
Postmarket guidance addresses vulnerability monitoring, coordinated disclosure, patching, and when changes constitute a recall vs. a routine update. Expect ISAO membership, a documented vulnerability handling process, and a coordinated disclosure policy.
Provide SBOMs in a machine-readable format such as SPDX or CycloneDX. Include all third-party components (open source and commercial), versions, and known vulnerabilities. Refresh on each release and on disclosure of new vulnerabilities in shipped components. SBOMs ingested into vulnerability monitoring tools enable rapid impact assessment when a new CVE drops.
The HIMSS/NEMA MDS² form is a standardized vendor disclosure of security capabilities of a medical device — used by hospitals during procurement and risk assessment. Maintain MDS² forms for devices you produce; request them for devices you procure.
The single most impactful network control in a hospital. Without it, a ransomware infection on a finance laptop reaches an infusion pump.
| Zone | Examples |
|---|---|
| Enterprise IT | Workstations, email, productivity, finance/HR |
| Clinical / EHR | EHR servers, clinical workstations, PACS |
| Medical devices (managed) | Infusion pumps, monitors, imaging modalities |
| Medical devices (legacy/unsupported) | Older modalities, lab analyzers — often un-patchable |
| OT / building / IoT | HVAC, badge access, IP cameras |
| Research / academic | Lower-trust networks isolated from clinical |
| Guest / patient Wi-Fi | Public, internet-only |
Segmentation principles:
| Standard | Scope |
|---|---|
| IEC 80001-1 | Application of risk management for IT-networks incorporating medical devices — assigns responsibilities to the healthcare delivery organization, manufacturer, and IT provider |
| IEC 80001-x series | Specific guidance on wireless networks, security, etc. |
| IEC 62443 | OT cybersecurity (originally industrial control systems; widely applied to medical-device-bearing networks) — zones, conduits, security levels, lifecycle |
Use these when designing the hospital network that hosts medical devices. They assign responsibility across HDO, manufacturer, and integrator — useful for clarifying who must do what.
Zero trust principles (verify explicitly, least privilege, assume breach) apply, with healthcare-specific tradeoffs:
Adopt incrementally: identity hardening (MFA, conditional access, PAM) first; micro-segmentation next; per-request authorization for sensitive PHI flows over time.
| Control | Healthcare specifics |
|---|---|
| MFA on all remote access | Required by recognized practices and many cyber-insurance policies |
| MFA on email and admin accounts | Stops the bulk of credential-phishing follow-on |
| Phishing-resistant MFA (FIDO2/WebAuthn, smart cards) | For privileged accounts and high-risk roles |
| SSO with conditional access | Risk-based step-up (device posture, geo, impossible-travel) |
| Privileged Access Management (PAM) | Vaulted creds for domain admin, hypervisor admin, EHR DB admin; session recording; just-in-time elevation |
| Service accounts | Inventoried, scoped, secret-rotated; remove interactive logon where unnecessary |
| EHR-specific privileged roles | Break-the-glass procedures, audit override roles, system-build accounts |
Compromised credentials remain the most common ransomware entry path in healthcare. Pair MFA with PAM and conditional access for the credentials attackers actually want.
See hipaa-compliance for BAA mechanics and hitrust-csf for cross-framework evidence reuse.
Ransomware in healthcare is a patient-safety event, not just an IT event.
Coordinate early with:
| Control | Why it matters |
|---|---|
| ATNA audit + SIEM integration | Required for §164.312(b); see audit-logging |
| DICOM with TLS + node authentication | Imaging trust boundary |
| Secure FHIR (TLS + OAuth/SMART) | API trust boundary |
| Tap-and-go workstation auth | Clinical UX without insecure shared logins |
| Mobile device management (MDM) on clinical mobiles | Encryption, remote wipe, jailbreak detection |
| USB / removable media policy | Common exfiltration / malware vector |
| Outbound DLP for PHI | Mail, cloud uploads, chat |
When advising on a cybersecurity question:
~30 seconds. Free. No account. Every finding cites a rule and a line of evidence.